Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Immunol Methods ; 525: 113606, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38145790

RESUMO

Tumor-associated glycoprotein 72 (TAG-72) is a mucin that is overexpressed heterogeneously on the surface of cancer cells, and is a potential target for immunotherapies for various cancer types. As a tumor marker, TAG-72 is measured with the cancer antigen (CA) 72-4 immunoassay. The murine monoclonal antibody (mAb) CC49 is a second-generation IgG that targets an antigen on TAG-72; however, CC49 has an unfavorable propensity to aggregate, which results in antibody impurity, instability, and low solubility and thus low potency and efficacy for therapeutic and diagnostic applications. Sequence analysis of CC49 revealed aggregation-prone motifs in the variable domain of the light chain. Using antibody engineering approaches, we developed three aggregation-resistant CC49 mIgG2a mutants (CC49M1, CC49M2, and CC49M3). The engineered CC49 mIgG2a mutants retained compatible binding performance with a significantly higher thermal stability. The CC49 mIgG2a mutants also demonstrated an almost 15-fold improvement in solubility, with 97% purity vs 70% purity of the parent molecule at 0.3 mg/mL. The enhanced stability and improved solubility of engineered CC49 could have significant advantages for diagnostic and therapeutic applications.


Assuntos
Antígenos de Neoplasias , Glicoproteínas , Camundongos , Animais , Solubilidade , Antígenos de Neoplasias/genética , Anticorpos Monoclonais , Imunoglobulina G/genética
2.
Clin Proteomics ; 20(1): 53, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38017436

RESUMO

BACKGROUND: Diagnosis of liver disease at earlier stages can improve outcomes and reduce the risk of progression to malignancy. Liver biopsy is the gold standard for diagnosis of liver disease, but is invasive and sample acquisition errors are common. Serum biomarkers for liver function and fibrosis, combined with patient factors, may allow for noninvasive detection of liver disease. In this pilot study, we tested and validated the performance of an algorithm that combines GP73 and LG2m serum biomarkers with age and sex (GLAS) to differentiate between patients with liver disease and healthy individuals in two independent cohorts. METHODS: To develop the algorithm, prototype immunoassays were used to measure GP73 and LG2m in residual serum samples collected between 2003 and 2016 from patients with staged fibrosis and cirrhosis of viral or non-viral etiology (n = 260) and healthy subjects (n = 133). The performance of five predictive models using combinations of age, sex, GP73, and/or LG2m from the development cohort were tested. Residual samples from a separate cohort with liver disease (fibrosis, cirrhosis, or chronic liver disease; n = 395) and healthy subjects (n = 106) were used to validate the best performing model. RESULTS: GP73 and LG2m concentrations were higher in patients with liver disease than healthy controls and higher in those with cirrhosis than fibrosis in both the development and validation cohorts. The best performing model included both GP73 and LG2m plus age and sex (GLAS algorithm), which had an AUC of 0.92 (95% CI: 0.90-0.95), a sensitivity of 88.8%, and a specificity of 75.9%. In the validation cohort, the GLAS algorithm had an estimated an AUC of 0.93 (95% CI: 0.90-0.95), a sensitivity of 91.1%, and a specificity of 80.2%. In both cohorts, the GLAS algorithm had high predictive probability for distinguishing between patients with liver disease versus healthy controls. CONCLUSIONS: GP73 and LG2m serum biomarkers, when combined with age and sex (GLAS algorithm), showed high sensitivity and specificity for detection of liver disease in two independent cohorts. The GLAS algorithm will need to be validated and refined in larger cohorts and tested in longitudinal studies for differentiating between stable versus advancing liver disease over time.

3.
Clin Chem Lab Med ; 61(8): 1511-1517, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36799248

RESUMO

OBJECTIVES: To evaluate pre-analytical challenges related to high-volume central laboratory SARS-CoV-2 antigen testing with a prototype qualitative SARS-CoV-2 antigen immunoassay run on the automated Abbott ARCHITECT instrument. METHODS: Contrived positive and negative specimens and de-identified nasal and nasopharyngeal specimens in transport media were used to evaluate specimen and reagent on-board stability, assay analytical performance and interference, and clinical performance. RESULTS: TCID50/mL values were similar for specimens in various transport media. Inactivated positive clinical specimens and viral lysate (USA-WA1/2020) were positive on the prototype immunoassay. Within-laboratory imprecision was ≤0.10 SD (<1.00 S/C) with a ≤10% CV (≥1.00 S/C). Assay reagents were stable on board the instrument for 14 days. No high-dose hook effect was observed with a SARS-CoV-2 stock of Ct 13.0 (RLU>1.0 × 106). No interference was observed from mucin, whole blood, 12 drugs, and more than 20 cross-reactants. While specimen stability was limited at room temperature for specimens with or without viral inactivation, a single freeze/thaw cycle or long-term storage (>30 days) at -20 °C did not adversely impact specimen stability or assay performance. Specificity of the prototype SARS-CoV-2 antigen immunoassay was ≥98.5% and sensitivity was ≥89.5% across two ARCHITECT instruments. Assay sensitivity was inversely correlated with Ct and was similar to that reported for the Roche Elecsys® SARS-CoV-2 Ag immunoassay. CONCLUSIONS: The prototype SARS-CoV-2 antigen ARCHITECT immunoassay is sensitive and specific for detection of SARS-CoV-2 in nasal and nasopharyngeal specimens. Endogenous proteases in mucus may degrade the target antigen, which limits specimen storage and transport times and complicates assay workflow.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Sensibilidade e Especificidade , Teste para COVID-19 , Imunoensaio
4.
Biotechniques ; 73(3): 136-141, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36004516

RESUMO

Mutations in the nucleocapsid of SARS-CoV-2 may interfere with antigen detection by diagnostic tests. We used several methods to evaluate the effect of various SARS-CoV-2 nucleocapsid mutations on the performance of the Panbio™ and BinaxNOW™ lateral flow rapid antigen tests and a prototype high-throughput immunoassay that utilizes Panbio antibodies. Variant detection was also evaluated by immunoblot and BIAcore™ assay. A panel of 23 recombinant nucleocapsid antigens (rAgs) were produced that included mutations found in circulating SARS-CoV-2 variants, including variants of concern. All mutant rAgs were detected by all assays, at a sensitivity equivalent to wild-type control (Wuhan strain). Thus, using a rAg approach, we found that the SARS-CoV-2 nucleocapsid mutations examined do not directly impact antigen detection or antigen assay performance.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , COVID-19/genética , Teste para COVID-19 , Testes Diagnósticos de Rotina , Humanos , Mutação , Nucleocapsídeo/genética , SARS-CoV-2/genética , Sensibilidade e Especificidade
5.
J Immunol Methods ; 504: 113262, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35341761

RESUMO

OBJECTIVES: Quantitative detection of interleukin-6 (IL-6) in serum and plasma can help monitor immune responses and the development of acute inflammation to guide patient management. We developed an IL-6 immunoassay for use with the automated ARCHITECT system for detecting an increase in the inflammatory response. METHODS: Immunized mouse sera were tested and selected B-cells were harvested for fusion with myeloma cells. A panel of monoclonal antibodies were produced, from which capture and detection monoclonal antibodies for the prototype IL-6 immunoassay were selected and screened on the ARCHITECT instrument. The antibody pair that most effectively captured and detected IL-6 was selected to develop a prototype IL-6 immunoassay. Calibrator and panel preparations using an internal recombinant IL-6 standard were compared to serum panels prepared with the IL-6 International Standard 89/548. Assay specificity and spike recovery were determined, and assay sensitivity was compared with the Roche EUA Elecsys IL-6 assay run on the cobas analyzer. RESULTS: Twenty-one antibodies in 441 antibody pairs were screened. The prototype IL-6 assay showed high sensitivity with an estimated limit of detection of 0.317 pg/mL and limit of quantitation of <1.27. Spike recovery was 90%-110% in serum and plasma. The internal recombinant human IL-6 calibrator showed excellent stability for 63 days at 2-8 °C. The prototype IL-6 immunoassay was specific for IL-6, exhibited no cross reactivity to related cytokines and interleukins, and was 10-fold more sensitive than the Elecsys IL-6 assay. CONCLUSIONS: The prototype ARCHITECT IL-6 automated immunoassay is a reliable and robust method for the quantitative determination of IL-6 in human serum and plasma.


Assuntos
Testes Imunológicos , Interleucina-6 , Animais , Anticorpos Monoclonais , Humanos , Imunoensaio/métodos , Fatores Imunológicos , Camundongos , Sensibilidade e Especificidade
6.
Biotechniques ; 71(1): 370-375, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34139879

RESUMO

Inactivation of SARS-CoV-2 virus is necessary to mitigate risk but may interfere with diagnostic assay performance. We examined the effect of heat inactivation on a prototype SARS-CoV-2 antigen immunoassay run on the ARCHITECT automated analyzer. Recombinant full-length SARS-CoV-2 nucleocapsid protein and virus lysate detection was reduced by 66 and 31%, respectively. Several nonionic detergents were assessed as inactivation alternatives based on infectivity in cultured Vero CCL81 cells. Incubation of SARS-CoV-2 in 0.1% Tergitol 15-S-9 for 10 min significantly reduced infectivity and increased the immunoassay signal for cultured lysate and patient specimens. Tergitol 15-S-9 can inactivate SARS-CoV-2 while preserving epitopes on the nucleocapsid protein for enhanced detection by immunoassay antibodies.


Assuntos
Teste para COVID-19/métodos , Poloxaleno/farmacologia , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/imunologia , Inativação de Vírus/efeitos dos fármacos , Animais , Anticorpos Antivirais/efeitos dos fármacos , Anticorpos Antivirais/imunologia , COVID-19/diagnóstico , COVID-19/imunologia , Teste para COVID-19/normas , Células Cultivadas , Chlorocebus aethiops , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Nucleocapsídeo/imunologia , Tensoativos/farmacologia , Células Vero
7.
Clin Proteomics ; 16: 2, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30675135

RESUMO

BACKGROUND: The biomarkers alpha-fetoprotein (AFP) and protein induced by vitamin K absence/antagonist-II (PIVKA-II) may be useful for detecting early-stage hepatocellular carcinoma (HCC). We evaluated the performance of AFP and PIVKA-II levels, alone and in combination with clinical factors, for the early detection of HCC. METHODS: In a case-control study, serum AFP and PIVKA-II were measured using the ARCHITECT immunoassay analyzer system in a cohort of 119 patients with HCC, 215 patients with non-malignant liver disease, and 34 healthy subjects. Five predictive models for detecting HCC were developed based on age, gender, AFP, and/or PIVKA-II levels; the best model was validated in an independent cohort of 416 patients with HCC and 412 control subjects with cirrhosis. RESULTS: In both cohorts, AFP and PIVKA-II concentrations were higher in patients with HCC compared to healthy controls and patients with non-malignant liver disease. The model that combined AFP and PIVKA-II, age, and gender had the highest AUC of 0.95 (0.95, 95% CI 0.93-0.98), with a sensitivity of 93% and a specificity of 84% in the development cohort, and an AUC of 0.87 (95% CI 0.85-0.90), sensitivity of 74%, and specificity of 85% in the validation cohort. When limiting the validation cohort to only early-stage HCC, the AUC was 0.85 (95% CI 0.81-0.88), sensitivity was 70%, and specificity was 86%. CONCLUSIONS: Compared to each biomarker alone, the combination of AFP and PIVKA-II with age and gender improved the accuracy of detecting HCC and differentiating HCC from non-malignant liver disease.

8.
Pract Lab Med ; 9: 58-68, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29159257

RESUMO

BACKGROUND: Dipeptidyl peptidase-4 (DPP-4) may be a suitable biomarker to identify people with severe asthma who have greater activation of the interleukin-13 (IL-13) pathway and may therefore benefit from IL-13-targeted treatments. We report the analytical performance of an Investigational Use Only immunoassay and provide data on the biological range of DPP-4 concentrations. METHODS: We assessed assay performance, utilising analyses of precision, linearity and sensitivity; interference from common endogenous assay interferents, and from asthma and anti-diabetic medications, were also assessed. The assay was used to measure the range of serum DPP-4 concentrations in healthy volunteers and subjects with diabetes and severe, uncontrolled asthma. RESULTS: The total precision of DPP-4 concentration measurement (determined using percentage coefficient of variation) was ≤5% over 20 days. Dilution analysis yielded linear results from 30 to 1305 ng/mL; the limit of quantitation was 19.2 ng/mL. No notable endogenous or drug interferences were observed at the expected therapeutic concentration. Median DPP-4 concentrations in healthy volunteers and subjects with asthma or Type 1 diabetes were assessed, with concentrations remaining similar in subjects with diabetes and asthma across different demographics. CONCLUSION: These analyses indicate that the ARCHITECT DPP-4 Immunoassay is a reliable and robust method for measuring serum DPP-4 concentration.

9.
Clin Chim Acta ; 464: 228-235, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27751727

RESUMO

BACKGROUND: Periostin is being investigated as a potential biomarker for T-helper-2 (Th2)-driven asthma or eosinophilic inflammation and may help to identify patients more likely to benefit from interleukin-13-targeted treatments. We report the development and analytic performance of the investigational use only ARCHITECT Periostin Immunoassay, a new automated assay developed to detect serum periostin concentrations. METHODS: We assessed assay performance in terms of precision, sensitivity, linearity, interference from classical immunoassay interferents and representatives of common asthma medications, specimen handling, and isoform reactivity. The assay was also used to assess the biological variability of serum periostin concentrations in samples from healthy volunteers and from subjects with uncontrolled asthma (the intended use population). RESULTS: The percentage CVs for 5-day total precision, assessed using two instruments, was <6% across 2 controls and one serum-based panel. Limit of quantitation was 4ng/mL (dilution adjusted concentration), suiting the needs for this application. Dilution analysis yielded linear results and no endogenous sample or drug interferences were observed. All known periostin isoforms expressed in the mature human lung were detected by the assay. CONCLUSION: Our studies provide support that the ARCHITECT Periostin Immunoassay is a reliable and robust test for measuring serum periostin concentrations.


Assuntos
Análise Química do Sangue/métodos , Moléculas de Adesão Celular/sangue , Imunoensaio/métodos , Adolescente , Asma/sangue , Automação , Biomarcadores/sangue , Coleta de Amostras Sanguíneas , Estudos de Casos e Controles , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Temperatura
10.
J Clin Oncol ; 29(7): 909-16, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21282543

RESUMO

PURPOSE: Resistance to chemotherapy-induced apoptosis represents a major obstacle to cancer control. Overexpression of Bcl-2 is seen in multiple tumor types and targeting Bcl-2 may provide therapeutic benefit. A phase I study of navitoclax, a novel inhibitor of Bcl-2 family proteins, was conducted to evaluate safety, pharmacokinetics, and preliminary efficacy in patients with solid tumors. PATIENTS AND METHODS: Patients enrolled to intermittent dosing cohorts received navitoclax on day -3, followed by dosing on days 1 to 14 of a 21-day cycle. Patients on continuous dosing received a 1-week lead-in dose of 150 mg followed by continuous daily administration. Blood samples were collected for pharmacokinetic analyses, biomarker analyses, and platelet monitoring. RESULTS: Forty-seven patients, including 29 with small-cell lung cancer (SCLC) or pulmonary carcinoid, were enrolled between 2007 and 2008, 35 on intermittent and 12 on continuous dosing cohorts. Primary toxicities included diarrhea (40%), nausea (34%), vomiting (36%), and fatigue (34%); most were grade 1 or 2. Dose- and schedule-dependent thrombocytopenia was seen in all patients. One patient with SCLC had a confirmed partial response lasting longer than 2 years, and eight patients with SCLC or carcinoid had stable disease (one remained on study for 13 months). Pro-gastrin releasing peptide (pro-GRP) was identified as a surrogate marker of Bcl-2 amplification and changes correlated with changes in tumor volume. CONCLUSION: Navitoclax is safe and well tolerated, with dose-dependent thrombocytopenia as the major adverse effect. Preliminary efficacy data are encouraging in SCLC. Efficacy in SCLC and the utility of pro-GRP as a marker of treatment response will be further evaluated in phase II studies.


Assuntos
Compostos de Anilina/administração & dosagem , Genes bcl-2/efeitos dos fármacos , Neoplasias/genética , Carcinoma de Pequenas Células do Pulmão/tratamento farmacológico , Carcinoma de Pequenas Células do Pulmão/genética , Sulfonamidas/administração & dosagem , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Compostos de Anilina/efeitos adversos , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Humanos , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Neoplasias/tratamento farmacológico , Neoplasias/mortalidade , Prognóstico , Medição de Risco , Carcinoma de Pequenas Células do Pulmão/mortalidade , Sulfonamidas/efeitos adversos , Análise de Sobrevida , Resultado do Tratamento
11.
Clin Chem Lab Med ; 49(4): 711-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21231906

RESUMO

BACKGROUND: Golgi protein-73 (GP73) and fucosylated proteins have been proposed as potential serum markers for liver disease and/or hepatocellular carcinoma (HCC). The purpose of this study was to compare the sensitivity and specificity of serum GP73 and fucosylated hemopexin (Fuc-HPX) with α-fetoprotein (AFP) and with protein induced by the absence of vitamin K or antagonist-II (PIVKA-II) for diagnosing chronic hepatitis, cirrhosis, and HCC. METHODS: The concentration of GP73 in human sera was determined using an enzyme-linked immunosorbent assay employing mouse monoclonal and rabbit polyclonal GP73 antibodies. Fuc-HPX was detected using a lectin chemiluminescence-linked immunosorbent assay using a mouse monoclonal anti-hemopexin antibody and Aleuria aurantia lectin. A total of 229 serum samples from patients with chronic hepatitis, cirrhosis, and HCC, as well as from normal individuals were evaluated using these four markers. RESULTS: GP73 and Fuc-HPX showed significantly higher values in samples from patients with cirrhosis and HCC than in samples from patients with hepatitis and from normal individuals. The areas under the curves (AUCs) for GP73, Fuc-HPX, AFP, and PIVKA-II were 0.90, 0.77, 0.74, and 0.88, respectively, for liver cirrhosis and HCC samples vs. hepatitis and normal samples. The AUCs of GP73, Fuc-HPX, AFP, and PIVKA-II were 0.78, 0.72, 0.81, and 0.90, respectively, for HCC samples vs. all other samples. CONCLUSIONS: PIVKA-II showed superior sensitivity and specificity for HCC compared with the other three markers. GP73 may be useful for detecting cirrhosis as a risk factor for HCC. Fuc-HPX showed inferior sensitivity and specificity compared to the other markers.


Assuntos
Análise Química do Sangue/métodos , Carcinoma Hepatocelular/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Hepatite Crônica/sangue , Neoplasias Hepáticas/sangue , Proteínas de Membrana/sangue , Animais , Biomarcadores/sangue , Análise Química do Sangue/normas , Carcinoma Hepatocelular/diagnóstico , Ensaio de Imunoadsorção Enzimática/normas , Fibrose , Hemopexina/análise , Hemopexina/química , Hepatite Crônica/diagnóstico , Humanos , Neoplasias Hepáticas/diagnóstico , Medições Luminescentes , Precursores de Proteínas/sangue , Protrombina , Curva ROC , Padrões de Referência , alfa-Fetoproteínas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA